← Back to Todd's Solar, Gear, & Travel
Home · Reviews · The DIY King for Home Solar Installs
Transfer Switch / Home Solar Build
The DIY King for Home Solar Installs: Nature's Generator Transfer Switch, EG4 12000XP & ECO-WORTHY EC100 Contactor Setup
Check Current Price
The 3 Pillars of the DIY King Build
- #1 — EG4 12000XP + EG4 WallMount 280Ah batteries (the heart). The 12 kW split-phase inverter and UL-listed WallMount batteries that run my house — together a fully UL 9540 system-listed energy storage setup. Full write-ups: EG4 12000XP Whole-Home Inverter Review (video) and EG4 WallMount 280Ah Batteries Review (part 1 · part 2).
- #2 — Nature's Generator 50A 240V 12,000W transfer switch (the distribution). Sits next to my main panel so I can flip individual house circuits between the utility grid and the 12000XP on the fly — the video above.
- #3 — ECO-WORTHY EC100 charger + $17 contactor (the glue). Grid charging goes AC → DC straight into the batteries through the EC100, switched on and off automatically by the 12000XP's generator dry contact. That's what makes this build impossible to backfeed and nearly zero idle draw — see the 3 contactor videos below.
The Big Takeaway — Why the EC100 + Contactor Makes This the DIY King
#1 It is impossible to backfeed the grid. I never land grid AC on the EG4 12000XP's AC/grid input for charging. Instead, grid power from a regular house breaker feeds the ECO-WORTHY EC100 — a one-way AC-to-DC battery charger — and its DC output goes straight onto the 48V battery bus, bypassing the inverter's AC side entirely. A charger like that acts as a one-way electrical valve: energy can only flow from the grid into the batteries, never from the batteries back out through the charger to the utility. The 12000XP's output only ever reaches house circuits through the transfer switch, which is break-before-make per circuit. So the inverter is never tied to the grid at all — the easiest, cleanest way for a DIY homeowner to prove zero grid backfeed.
#2 The contactor hack kills idle draw to ~3–4 watts. A big 48V 100A charger left energized 24/7 burns standby power, and the EG4 Chargeverter I tested idled even worse. So I use the EG4 12000XP's programmable generator (Gen) dry contact — that dry contact is the whole reason behind my 3-part contactor series. When the batteries drop to my start threshold (25% SOC), the 12000XP closes the dry contact, which energizes the coil of a $17 UL-listed contactor from Menards, which in turn powers up the EC100. At my stop threshold (35% SOC) the dry contact opens, the contactor drops out, and the EC100 is completely disconnected from AC — solar does the rest from 35% to 100%. While it waits, the only thing left drawing off the EG4 batteries is the tiny control loop: roughly 3–4 watts, almost non-existent.
Result: 100% provable zero grid backfeed + near-zero idle draw + simple, inspector-friendly parts = the best way I've found for a DIYer to run a truly off-grid home system that still uses the grid as an automatic fail-safe. That's why I call it the DIY King for home installs.
Verify the contactor rating for your own setup — I show the exact Menards contactor I used in the videos but intentionally don't list a SKU.
The 3 Contactor Switch Videos (EC100 + EG4 12000XP Gen Dry Contact)
Part 1: $17 AUTO ON & OFF EC100 CHARGER with EG4 1200XP HACK! NO idle draw! NO backfeeding!
Published Oct 18, 2026 · 7,386 views
Part 2: BUT WHAT ABOUT DC WATTAGE IDLE WITH $17 CONTACTOR 12000XP EC100 CHARGER HACK!?!?
Published Oct 21, 2026 · 587 views
Part 3: 240volt 2amp FUSES for $17contactor EG4 12000XP / EC100 CHARGER HACK!
Published Oct 29, 2026 · 962 views
Pros — Nature's Generator Transfer Switch
- Easy and fast to install — very doable for the average DIYer / layman
- Switch individual circuits on the fly between grid and solar/inverter power
- Lighted buttons show at a glance which circuits are on solar vs. grid
- Looks clean and finished on the wall
- Generally accepted by most electrical inspectors
- 50A 240V / 12,000W rating handles big 240V loads like a well pump, water heater, or central AC
Cons
- Switches only the hot leg — GFCI trips and possible backfeed if you also grid-charge the 12000XP. A manual circuit transfer switch like this switches only the hot conductor of each circuit; the neutrals (and grounds) stay tied back to your main panel's neutral bar, where neutral and ground are bonded. If you also run a breaker from that same main panel into the 12000XP's AC/grid input to charge from the grid, you've now connected the grid and the inverter's output through a shared, unswitched neutral. That creates parallel neutral paths — return current splits between the inverter's neutral and the panel's neutral — so the current through a GFCI's hot and neutral no longer matches and GFCI outlets/breakers nuisance-trip. Worse, unswitched neutrals and a grid-tied AC input give a low-impedance path back toward the utility side, so a wiring mistake or fault can create a potential backfeed path. This is exactly why I don't feed grid AC into the 12000XP at all and use the AC-to-DC EC100 + contactor instead. (Even a subpanel that shares the main panel's neutral/ground can have the same issue if the inverter is also grid-charging from that panel.)
- More expensive than a critical-loads subpanel. For the same number of circuits, a subpanel and breakers usually cost less than a pre-built transfer switch. A subpanel may be the better choice for some setups — see the comparison below.
Transfer Switch vs. Critical-Loads Subpanel
Nature's Generator Transfer Switch
Pros
- Fast, beginner-friendly install with pre-wired circuits
- Flip any circuit between grid and solar on the fly — no extra hardware
- Lighted buttons, clean look, widely accepted by inspectors
- Easy fallback: any circuit can go back to the grid with one switch
Cons
- Higher hardware cost
- Switches only the hot — shared neutrals with the main panel (GFCI/backfeed concerns if you also grid-charge the inverter)
- Limited to its fixed number of circuits and amp rating
Critical-Loads Subpanel
Pros
- Lower hardware cost — a panel and standard breakers
- Moves the whole circuit (hot and neutral) to the inverter when wired properly — fewer shared-neutral headaches and friendlier to GFCI/AFCI breakers
- Handles big 240V loads and is easy to expand with more breaker spaces
Cons
- Harder for a DIYer — you have to move hots, neutrals, and grounds from the main panel
- Needs an upstream interlock or transfer switch to get back to grid power
- No instant, circuit-by-circuit lighted switching on the fly
Top 5 Affiliate Links
The gear, parts, and tools I used in the transfer switch and 3 contactor videos, straight from my video descriptions. The main products are linked under Check Current Price above. The contactor itself came from Menards (see the video).
Bottom Line
Build the heart (EG4 12000XP + UL 9540 WallMount batteries), distribute it with the Nature's Generator transfer switch, and tie it together with an ECO-WORTHY EC100 on a contactor driven by the 12000XP's gen dry contact. You get grid charging as an automatic fail-safe with zero way to backfeed and ~3–4 W of idle draw — the DIY King setup for home solar.
Electrical work is dangerous. Shut off mains, verify zero voltage, follow the manufacturer manuals and local code, and use a licensed electrician if you are not qualified.
Related Videos
- DETAILED How I Wired My EG4 12000XP House Inverter Start to Finish!
- I SWAPPED OUT MY NON UL-LISTED FOR UL-LISTED EG4 280AH POWER PRO LiFePO4 BATTERIES WITH INSTALL!
- NOW 43,000 watt hours! LiFepo4 EG4 Add on Wall Mount Battery Full Installation!
- HOW I HARDWIRED MY ECOWORTHY EC100 48V BATTERY CHARGER DIRECT INTO AC PANEL
- DO YOU HAVE NO GRID POWER NO SUN BACKUP PLAN? ECOWORTHY EC100 - DRAGON OFF GRID SOLAR ADAPTER CABLE!
- LiFePo4 battery "bonded neutral" when charging WARNING when hooked up to house transfer switch!
More Reviews on This Site
Electrical & DIY Safety Disclaimer All content on this site and in related videos — including reviews, diagrams, and wiring examples — is for informational and entertainment purposes only and is not professional electrical or engineering advice. High-voltage AC/DC electrical work, batteries, inverters, transfer switches, and DIY installations can cause electric shock, fire, property damage, serious injury, or death if performed incorrectly. Always follow manufacturer instructions, local building and electrical codes, and National Electrical Code (NEC) requirements, and consult a licensed electrician before installing or modifying any electrical equipment. You assume all risk and liability for any installation, modification, or use of this information.